UPT 6-PE(Euro Style Spring Loaded Finger Safe Heat Resistant ground type termina block)

Products Details

Part name: Housing Material: PA66(UL94V-0)Operating temperature: -40℃~+105℃ Altitude: Less than 2000m 40Kpa~80KPa Relative Humidity : 5%~95% Pollution Degree: Ⅲ Package: Tightly Sealed
Product Description
Product Image    
Product Number UPT-6PE UPT-6/2-2
Product Type Rail wiring distribution block Rail wiring distribution block
Mechanical Structure Push-in spring connection Push-in spring connection
Layers 1 1
Electric Potential 1 1
Connection Volume 2 4
Rated Cross Section 6 mm2 6 mm2
Rated Current 41A 41A
Rated Voltage 1000V 1000V
Open Side Panel no no
Grounding Feet no no
Other The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 The connecting rail needs to install the rail foot F-NS35
Application Field Widely used in electrical connection, industrial Widely used in electrical connection, industrial
Color green、yellow gray、dark gray、green、yellow、cream、orange)、black、red、blue、white、purple、Brown、customizable
Wiring Data
Line Contact
Stripping Length 10mm — 12mm 10mm-12mm
Rigid Conductor Cross Section 0.5mm² — 10mm² 0.5mm² — 10mm²
Flexible Conductor Cross Section 0.5mm² — 10mm² 0.5mm² — 10mm²
Rigid Conductor Cross Section AWG 20-8 20-8
Flexible Conductor Cross Section AWG 20-8 20-8
Size (This Is The Dimension Of The UPT-6PE)
Thickness 57.72mm 8.2mm
Width 8.15mm 90.5mm
High 42.2mm 42.2mm
NS35/7.5 High 31.1mm 51mm
NS35/15 High 38.6mm 43.5mm
NS15/5.5 High    
Material Properties
Flame Retardant Grade, In Line With UL94 V0 V0
Insulation Materials PA PA
Insulation Material Group I I
 IEC Electrical Parameters
  Standard Test IEC IEC60947-1 ,  
Rated Voltage(III/3)   1000V
Rated Current(III/3)   41A
Rated Surge Voltage 8kv 8kv
Overvoltage Class III III
Pollution Level 3 3
Electrical Performance Test
Surge Voltage Test Results Passed the test Passed the test
Power Frequency Withstand Voltage Test Results Passed the test Passed the test
Temperature Rise Test Results Passed the test Passed the test
Environmental Conditions
Ambient Temperature (Operating) -40℃~+105℃(Depends on the derating curve) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient Temperature (Storage/Transport)  -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient Temperature (Assembled) -5 °C — 70 °C -5 °C — 70 °C
Ambient Temperature (Execution) -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % ... 70 % 30 % — 70 %
Environmental Friendly
RoHS No hazardous substances above threshold values No excessive harmful substances
Standards And Specifications
Connections Are Standard IEC 60947-7-1 IEC 60947-7-1

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours