Product Description | |||
Product Image | |||
Product Number | UPT-6PE | UPT-6/2-2 | UPT-6 |
Product Type | Rail wiring distribution block | Rail wiring distribution block | Push in din rail terminal block |
Mechanical Structure | Push-in spring connection | Push-in spring connection | Push-in spring connection |
Layers | 1 | 1 | 1 |
Electric Potential | 1 | 1 | 1 |
Connection Volume | 2 | 4 | 2 |
Rated Cross Section | 6 mm2 | 6 mm2 | 6mm2 |
Rated Current | 41A | 41A | 41A |
Rated Voltage | 1000V | 1000V | 1000V |
Open Side Panel | no | no | Yes |
Grounding Feet | no | no | no |
Other | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail foot F-NS35 | |
Application Field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
Color | (green)、(yellow) | (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable | (gray)、(Yellow and green)、customizable |
Wiring Data | |||
Line Contact | |||
Stripping Length | 10mm — 12mm | 10mm-12mm | 10mm — 12mm |
Rigid Conductor Cross Section | 0.5mm² — 10mm² | 0.5mm² — 10mm² | 0.5mm² — 10mm² |
Flexible Conductor Cross Section | 0.5mm² — 10mm² | 0.5mm² — 10mm² | 0.5mm² — 10mm² |
Rigid Conductor Cross Section AWG | 20-8 | 20-8 | 20-8 |
Flexible Conductor Cross Section AWG | 20-8 | 20-8 | 20-8 |
Size (This Is The Dimension Of The UPT-6PE) | |||
Thickness | 57.72mm | 8.2mm | 8.2mm |
Width | 8.15mm | 90.5mm | 57.7mm |
High | 42.2mm | 42.2mm | 42.2mm |
NS35/7.5 High | 31.1mm | 51mm | 51mm |
NS35/15 High | 38.6mm | 43.5mm | 43.5mm |
NS15/5.5 High |
Material Properties | |||
Flame Retardant Grade, In Line With UL94 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA |
Insulation Material Group | I | I | I |
IEC IEC Electrical Parameters | |||
Standard Test | IEC IEC60947-1 , | IEC 60947-7-1 | |
Rated Voltage(III/3) | 1000V | 1000V | |
Rated Current(III/3) | 41A | 41A | |
Rated Surge Voltage | 8kv | 8kv | 8kv |
Overvoltage Class | III | III | III |
Pollution Level | 3 | 3 | 3 |
Electrical Performance Test | |||
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test |
Power Frequency Withstand Voltage Test Results | Passed the test | Passed the test | Passed the test |
Temperature Rise Test Results | Passed the test | Passed the test | Passed the test |
Environmental Conditions | |||
Ambient Temperature (Operating) | -40℃~+105℃(Depends on the derating curve) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient Temperature (Storage/Transport) | -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient Temperature (Assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient Temperature (Execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % ... 70 % | 30 % — 70 % | 30 % — 70 % |
Environmental Friendly | ||
RoHS | No hazardous substances above threshold values | No excessive harmful substances |
Standards And Specifications | |||
Connections Are Standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |