| Product Image | |||
| Product number | UPT-2.5/1P | UPT-2.5K | UPT-2.5/1-2K |
| product type | Rail wiring distribution block | Rail wiring distribution block | Rail wiring terminal block |
| Mechanical structure | Push-in spring connection | Push-in spring connection | Push-in spring connection |
| layers | 1 | 1 | 1 |
| Electric potential | 1 | 1 | 1 |
| connection volume | 2 | 2 | 3 |
| Rated cross section | 2.5 mm2 | 2.5mm2 | 2.5 mm2 |
| Rated current | 24A | 20A | 20A |
| Rated voltage | 500V | 400V | 400V |
| open side panel | no | no | no |
| grounding feet | no | no | no |
| other | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 | No |
| Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
| color | (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable | (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable | (gray)、customizable |
| Wiring data | |||
| line contact | |||
| Stripping length | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm |
| Rigid Conductor Cross Section | 0.14mm² — 4mm² | 0.14mm² — 4mm² | 0.14mm² — 4mm² |
| Flexible conductor cross section | 0.14mm² — 4mm² | 0.14mm² — 4mm² | 0.14mm² — 2.5mm² |
| Rigid Conductor Cross Section AWG | 26-12 | 26-12 | 26-12 |
| Flexible Conductor Cross Section AWG | 26-14 | 26-14 | 26-14 |
| size (this is the dimension of the UPT-2.5 carrying rail foot F-NS35 installed on the rail) | |||
| thickness | 5.2mm | 5.2mm | 5.2mm |
| width | 45.5mm | 62mm | 73.7mm |
| high | 21.7mm | 35.3mm | 35.25mm |
| NS35/7.5 high | 44mm | 44mm | |
| NS35/15 high | 36.5mm | 36.5mm | |
| NS15/5.5 high | |||
| Material properties | |||
| Flame retardant grade, in line with UL94 | V0 | V0 | V0 |
| Insulation Materials | PA | PA | PA |
| Insulation material group | I | I | I |
| IEC IEC Electrical parameters | |||
| standard test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
| Rated voltage(III/3) | 500V | 400V | 400V |
| Rated current(III/3) | 24A | 20A | 20A |
| Rated surge voltage | 8kv | 8kv | 6kv |
| Overvoltage class | III | III | III |
| pollution level | 3 | 3 | 3 |
| Electrical performance test | |||
| Surge Voltage Test Results | Passed the test | Passed the test | Passed the test |
| Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test |
| Temperature rise test results | Passed the test | Passed the test | Passed the test |
| environmental conditions | |||
| Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
| Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
| Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
| Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
| Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
| Environmental friendly | |||
| RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
| Standards and Specifications | |||
| Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |