JUT15-18X2.5-P(Low Voltage Panel Mount push-in distribution terminal block Din Rail terminals block electrical connectors )

For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts. Working current: 24 A, Operating Voltage: 690 V. Wiring method: Push-in spring connection. Rated wiring capacity: 2.5mm2. Installation method: NS 35/7.5, NS 35/15.

Products Details

Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space. It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use. Time-saving wire connection thanks to tool-free push-in connection technology. Modules can be installed immediately without manual bridging, saving up to 80% of time. Different colors, the wiring is more clear.
Connection method In-line
Number of rows 1
Electric Potential 1
Number of connections 18
Open side panel NO
Insulation Materials PA
Flame retardant grade, in line with UL94 V0
Application field Widely used in electrical connection, industry, etc.
Color gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown
Load contact
Stripping length 8 mm — 10 mm
Rigid Conductor Cross Section 0.14 mm² — 4 mm²
Flexible conductor cross section 0.14 mm² — 2.5 mm²
Rigid Conductor Cross Section AWG 26 — 12
Flexible Conductor Cross Section AWG 26 — 14
Thickness 28.8mm
Width 58.5mm
Height 21.7mm
NS35/7.5 High 32.5mm
NS35/15 High 40mm
NS15/5.5 High 30.5mm
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 %
Flame retardant grade, in line with UL94 V0
Insulation Materials PA
Insulation material group I
Surge Voltage Test Results Passed the test
Power frequency withstand voltage test results Passed the test
Temperature rise test results Passed the test
RoHS No excessive harmful substances
1. The maximum load current of a single clamping device must not be exceeded. 2. When installing multiple terminals side by side, it is recommended to install a DIN rail adapter below the terminal point, or a flange between the terminals.
Connections are standard IEC 60947-7-1
Standard test IEC 60947-7-1
Rated voltage(III/3) 690V
Rated current(III/3) 24A
Rated surge voltage 8kv
Overvoltage class III
pollution level 3

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours