Product number | JUT1-50 | JUT1-50PE | JUT1-50T |
product type | High current rail terminal block | High current rail ground terminal | High Current Right Angle Terminal Blocks |
Mechanical structure | screw type | screw type | screw type |
layers | 1 | 1 | 1 |
Electric potential | 1 | 1 | 1 |
connection volume | 2 | 2 | 2 |
Rated cross section | 50 mm2 | 50 mm2 | 50 mm2 |
Rated current | 150A | 150A | |
Rated voltage | 1000V | 1000V | |
open side panel | no | no | no |
grounding feet | no | Yes | no |
other | |||
Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
color | gray、customizable | yellow and green | gray、customizable |
Line contact | |||
Stripping length | 24mm | 24mm | 24mm |
Rigid Conductor Cross Section | 16mm² — 50mm² | 16mm² — 50mm² | 16mm² — 50mm² |
Flexible conductor cross section | 25mm² — 50mm² | 25mm² — 50mm² | 25mm² — 50mm² |
Rigid Conductor Cross Section AWG | 6-2/0 | 6-1/0 | 6-2/0 |
Flexible Conductor Cross Section AWG | 3-2/0 | 3-1/0 | 3-2/0 |
thickness | 20.2mm | 20mm | 18.8mm |
width | 71.3mm | 70.5mm | 66mm |
high | 91.5mm | ||
NS35/7.5 high | 77.2mm | 83.5mm | |
NS35/15 high | 84.7mm | 91mm | |
NS15/5.5 high |
Flame retardant grade, in line with UL94 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA |
Insulation material group | I | I | I |
Standard test | IEC 60947-7-1 | IEC 60947-7-2 | IEC 60947-7-1 |
Rated voltage(III/3) | 1000V | 1000V | |
Rated current(III/3) | 150A | 150A | |
Rated surge voltage | 8kv | 8kv | 8kv |
Overvoltage class | III | III | III |
pollution level | 3 | 3 | 3 |
Surge Voltage Test Results | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test | Passed the test |