JUT1-10 series (Terminal Blocks For Model Railways plug in terminal block screw and wire terminals)

The screw-type industrial terminal block has strong static connection stability, high versatility, and can be quickly installed on U-shaped guide rails and G-shaped guide rails. Abundant and practical accessories. Traditional and reliable. Working current: 57 A, Operating Voltage: 800V Wiring method: screw connection. Rated wiring capacity: 10 mm2 Installation method: NS 35/7.5, NS 35/15, NS32.

Products Details

Universal mounting foot, available for rails NS35 and NS32. Static connection stability is strong. Potential distribution with bridges.
Product number JUT1-10 JUT1-10PE JUT1-10RD
product type Rail Terminals Rail ground terminal Rail ground terminal
Mechanical structure screw type screw type screw type
layers 1 1 1
Electric Potential 1 1 1
connection volume 2 2 2
Rated cross section 10 mm2 10 mm2 10mm2
Rated current 57A 10A
Rated voltage 800V 800V
open side panel yes no no
grounding feet no yes no
other for fuse size G/5x20
Application field electricity, mechanical engineering, factory engineering, process industry, etc.
color gray, customizable yellow and green black, customizable
line contact
Stripping length 10mm 10mm 10mm
Rigid Conductor Cross Section 0.5mm² — 16mm² 0.5mm² — 10mm² 0.5mm² — 10mm²
Flexible conductor cross section 0.5mm² — 10mm² 0.5mm² — 6mm² 0.5mm² — 10mm²
Rigid Conductor Cross Section AWG 20-6 20-8 24-6
Flexible Conductor Cross Section AWG 20-8 20-10 24-6
thickness 10.2mm 10.2mm 12mm
width 42.5mm 42.5mm 62mm
high
NS35/7.5 high 47mm 47mm 57mm
NS35/15 high 54.5mm 54.5mm 64.5mm
NS15/5.5 high
Flame retardant grade, in line with UL94 V0 V0 V0
Insulation Materials PA PA PA
Insulation material group I I I
standard test IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-3
Rated voltage(III/3) 800V 800V
Rated current(III/3) 57A 10A
Rated surge voltage 8kv 8kv 8kv
Overvoltage class III III III
pollution level 3 3 3
Surge Voltage Test Results -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 25 % — 75 %
RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances
Connections are standard IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-3
Surge Voltage Test Results Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours