Product Image | |||
Product number | JUT2-6 | JUT2-6PE | JUT2-6S |
product type | Din rail terminal block | PE terminal block | Test terminal block |
Mechanical structure | screw type | screw type | screw type |
layers | 1 | 1 | 1 |
Electric potential | 1 | 1 | 1 |
connection volume | 2 | 2 | 2 |
Rated cross section | 6 mm2 | 6 mm2 | 6mm2 |
Rated current | 41A | 41A | |
Rated voltage | 800V | 500V | |
open side panel | yes | no | yes |
grounding feet | no | yes | no |
other | The connecting rail needs to install the rail foot F-NS35 | ||
Application field | Widely used in electrical connection, industrial | ||
color | beige, customizable | Yellow/green | Beige, customizable |
Stripping length | 12mm | 12mm | 12mm |
Rigid Conductor Cross Section | 0.2mm² — 10mm² | 0.2mm² — 10mm² | 0.2mm² — 10mm² |
Flexible conductor cross section | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² |
Rigid Conductor Cross Section AWG | 24-10 | 24-8 | 24-8 |
Flexible Conductor Cross Section AWG | 24-10 | 24-8 | 24-8 |
thickness | 8mm | 8mm | 8mm |
width | 42mm | 40.7mm | 65mm |
high | |||
NS35/7.5 high | 47.5 mm | 47.7mm | 48.2mm |
NS35/15 high | 55mm | 55.2mm | 55.7mm |
NS15/5.5 high |
Flame retardant grade, in line with UL94 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA |
Insulation material group | I | I | I |
standard test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Rated voltage(III/3) | 800V | 500V | |
Rated current(III/3) | 41A | 41A | |
Rated surge voltage | 8kv | 8kv | 8kv |
Overvoltage class | III | III | III |
pollution level | 3 | 3 | 3 |
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test | Passed the test |
Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |