Product Image | ||
Product number | JUT14-1.5/DK/GY | JUT14-1.5 PE |
product type | Rail wiring distribution block | Rail wiring distribution block |
Mechanical structure | Push-in spring connection | Push-in spring connection |
layers | 1 | 1 |
Electric potential | 1 | 1 |
connection volume | 2 | 2 |
Rated cross section | 1.5 mm2 | 1.5 mm2 |
Rated current | 17.5A | |
Rated voltage | 800V | |
open side panel | Yes | no |
grounding feet | no | Yes |
other | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 |
Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
color | (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable | Green and Yellow |
Stripping length | 9mm — 10mm | 9mm — 10mm |
Rigid Conductor Cross Section | 0.2-2.5mm² | 0.2-2.5mm² |
Flexible conductor cross section | 0.2-1.5mm² | 0.2-1.5mm² |
Rigid Conductor Cross Section AWG | 24-14 | 24-14 |
Flexible Conductor Cross Section AWG | 24-16 | 24-16 |
size (this is the dimension of the JUT14-1.5 carrying rail foot F-NS35 installed on the rail) | ||
thickness | 4.2mm | 4.2mm |
width | 53.3mm | 46.92mm |
high | 35.6mm | 34mm |
NS35/7.5 high | 43.1 mm | 41.5mm |
NS35/15 high | 50.6mm | 49mm |
NS15/5.5 high |
Material properties | ||
Flame retardant grade, in line with UL94 | V0 | V0 |
Insulation Materials | PA | PA |
Insulation material group | I | I |
IEC Electrical parameters | ||
standard test | IEC 60947-7-1 | IEC 60947-7-1 |
Rated voltage(III/3) | 800V | |
Rated current(III/3) | 17.5A | |
Rated surge voltage | 6kv | 6kv |
Overvoltage class | III | III |
pollution level | 3 | 3 |
Electrical performance test | ||
Surge Voltage Test Results | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test |
environmental conditions | ||
Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -40℃~+105℃(Depends on the derating curve) |
Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % |
Environmental friendly | ||
RoHS | No excessive harmful substances | No hazardous substances above threshold values |
Standards and Specifications | ||
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 |