product description | ||||||
Product Image | ||||||
Product number | JUT11-80 | JUT11-125 | JUT11-160 | JUT11-250 | JUT11-400 | JUT11-500 |
product type | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block |
Mechanical structure | Power distribution terminal block | Power distribution terminal block | Power distribution terminal block | Power distribution terminal blockn | Power distribution terminal block | Power distribution terminal block |
layers | 1 | 1 | 1 | 1 | 1 | 1 |
Electric potential | 7 | 7 | 7 | 12 | 12 | 12 |
connection volume | 7 | 7 | 7 | 12 | 12 | 12 |
Rated cross section | - | - | - | - | - | - |
Rated current | 80A | 125A | 160A | 250A | 400A | 500A |
Rated voltage | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL |
open side panel | Yes | Yes | Yes | Yes | Yes | Yes |
grounding feet | no | no | no | no | no | no |
other | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 |
Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | |
color | (gray)、(blue)、customizable | (gray)、(blue)、customizable | (gray)、(blue)、customizable | (gray)、(blue)、customizable | (gray)、(blue)、customizable | (gray)、(blue)、customizable |
Wiring data | ||||||
line contact | ||||||
Mounting holes | 54mm | 64mm | 64mm | 85x29mm | 85x29mm | 85x29mm |
Rigid Conductor Cross Section | 6-16mm² | 10-35mm² | 10-70mm² | 35-120mm² | 95-185mm² | - |
Flexible conductor cross section | - | - | - | - | - | - |
Rigid Conductor Cross Section AWG | - | - | - | - | - | - |
Flexible Conductor Cross Section AWG | - | - | - | - | - | - |
size | ||||||
thickness | 46mm | 46mm | 46mm | 50mm | 50mm | 50mm |
width | 30mm | 29mm | 29mm | 49mm | 49mm | 49mm |
high | 65mm | 77mm | 77mm | 96mm | 96mm | 96mm |
NS35/7.5 high | 72.5mm | 84.5mm | 84.5mm | 103.5mm | 103.5mm | 103.5mm |
NS35/15 high | - | - | - | - | - | |
NS15/5.5 high |
Material properties | |||||
Flame retardant grade, in line with UL94 | V0 | V0 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA | PA | PA |
Insulation material group | I | I | I | I | I |
IEC Electrical parameters | ||||||
standard test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Rated voltage(III/3) | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL |
Rated current(III/3) | 80A | 125A | 160A | 250A | 400A | 500A |
Rated surge voltage | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL | 600V UL |
Overvoltage class | III | III | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 | 3 | 3 |
Electrical performance test | ||||||
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
environmental conditions | ||||||
Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % ... 70 % | 30 % — 70 % | 30 % — 70 % |
Environmental friendly | ||||||
RoHS | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values |
Standards and Specifications | |||||
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |