JUT1-6 series (Connecting Wires To Terminal Block Panel Mounted Feed Through Screw Cage Din Rail Terminal Block)

The screw-type industrial terminal block has strong static connection stability, high versatility, and can be quickly installed on U-shaped guide rails and G-shaped guide rails. Abundant and practical accessories. Traditional and reliable. Working current: 41 A, Operating Voltage: 800V. Wiring method: screw connection. Rated wiring capacity: 6 mm2 Installation method: NS 35/7.5, NS 35/15, NS32.

Products Details

Advantage of JUT1-10 Series

Universal mounting foot, available for rails NS35 and NS32.

Static connection stability is strong.

Potential distribution with bridges.

JUT1-10 Series

Product number JUT1-6 JUT1-6PE JUT1-6S
Product type Rail Terminals Rail ground terminal Test rail terminal block
Mechanical structure screw type screw type screw type
layers 1 1 1
Electric Potential 1 1 1
connection volume 2 2 2
Rated cross section 6 mm2 6 mm2 6mm2
Rated current 41A 41A
Rated voltage 800V 400V
open side panel yes no no
grounding feet no yes no
other when connecting the open housing side of modular screw rail grounding terminals of the same series and size, the terminal must be equipped with a cover if the insulation voltage is expected to be higher than 320 V. For fuse size G/5x20
Application field electricity, mechanical engineering, factory engineering, process industry, etc.
color gray, customizable yellow and green black, customizable

Wiring Data

line contact
Stripping length 10mm 10mm 13mm
Rigid Conductor Cross Section 0.2mm² — 10mm² 0.2mm² — 10mm² 0.5mm² — 10mm²
Flexible conductor cross section 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm²
Rigid Conductor Cross Section AWG 24-8 24-8 20-8
Flexible Conductor Cross Section AWG 24-12 24-10 20-10

Size

thickness 8.2mm 8.2mm 8.2mm
width 42.5mm 42.5mm 72mm
high
NS35/7.5 high 47mm 47mm 51.5mm
NS35/15 high 54.5mm 54.5mm 59mm
NS15/5.5 high

Material Properties

Flame retardant grade, in line with UL94 V0 V0 V0
Insulation Materials PA PA PA
Insulation material group I I I

IEC Electrical Parameters

standard test IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-1
Rated voltage(III/3) 800V 400V
Rated current(III/3) 41A 41A
Rated surge voltage 8kv 8kv 6kv
Overvoltage class III III III
pollution level 3 3 3

Electrical Performance Test

Surge Voltage Test Results Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test

Environmental Conditions

Surge Voltage Test Results -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 25 % — 75 %

Environmental Friendly

RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances

Standards and Specifications

Connections are standard IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-1