JUT15-6X2.5-P(Push-In Links, Distribution Blocks, Terminal Blocks, Distribution Boxes)

For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts. Working current: 24 A, Operating Voltage: 690 V. Wiring method: Push-in spring connection. Rated wiring capacity: 2.5mm2. Installation method: NS 35/7.5, NS 35/15.

Products Details

Advantage

Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space.

It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use.

Time-saving wire connection thanks to tool-free push-in connection technology.

Modules can be installed immediately without manual bridging, saving up to 80% of time.

Different colors, the wiring is more clear.

Overview

Connection method In-line
Number of rows 1
Electric Potential 1
Number of connections 6
Open side panel NO
Insulation Materials PA
Flame retardant grade, in line with UL94 V0
Application field Widely used in electrical connection, industry, etc.
Color gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown

Wiring Data

Load contact
Stripping length 8 mm — 10 mm
Rigid Conductor Cross Section 0.14 mm² — 4 mm²
Flexible conductor cross section 0.14 mm² — 2.5 mm²
Rigid Conductor Cross Section AWG 26 — 12
Flexible Conductor Cross Section AWG 26 — 14

Size

Thickness 28.8mm
Width 58.5mm
Height 21.7mm
NS35/7.5 High 32.5mm
NS35/15 High 40mm
NS15/5.5 High 30.5mm

Environmental conditions

Ambient temperature (operating) -60 °C — 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport) -25 °C — 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C
Permissible humidity (storage/transport) 30 % — 70 %

Material properties

Flame retardant grade, in line with UL94 V0
Insulation Materials PA
Insulation material group I

IEC Electrical parameters

Standard test IEC 60947-7-1
Pollution level 3
Overvoltage class III
Rated voltage(III/3) 690V
Rated current(III/3) 24A
Rated surge voltage 8kV

Electrical performance test

Requirements, voltage drop Passed the test
Voltage drop test results Passed the test
Temperature rise test results Passed the test

Environmental friendly

RoHS No excessive harmful substances

Standards and Specifications

Connections are standard IEC 60947-7-1

Precautions

1. The maximum load current of a single clamping device must not be exceeded.

2. When installing multiple terminals side by side, it is recommended to install a DIN rail adapter below the terminal point, or a flange between the terminals.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours