| Connection method | In-line | 
| Number of rows | 1 | 
| Electric Potential | 1 | 
| Number of connections | 4 | 
| Open side panel | NO | 
| Insulation Materials | PA | 
| Flame retardant grade, in line with UL94 | V0 | 
| Application field | Widely used in electrical connection, industry, etc. | 
| Color | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown | 
| Load contact | |
| Stripping length | 8 mm — 10 mm | 
| Rigid Conductor Cross Section | 0.14 mm² — 4 mm² | 
| Flexible conductor cross section | 0.14 mm² — 2.5 mm² | 
| Rigid Conductor Cross Section AWG | 26 — 12 | 
| Flexible Conductor Cross Section AWG | 26 — 14 | 
| Thickness | 14.3mm | 
| Width | 45.5mm | 
| Height | 21.7mm | 
| NS35/7.5 High | 31.1mm | 
| NS35/15 High | 38.6mm | 
| Ambient temperature (operating) | -60 °C — 105 °C (max. short-term operating temperature RTI Elec.) | 
| Ambient temperature (storage/transport) | -25 °C — 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | 
| Ambient temperature (assembled) | -5 °C — 70 °C | 
| Ambient temperature (execution) | -5 °C — 70 °C | 
| Permissible humidity (storage/transport) | 30 % — 70 % | 
| Flame retardant grade, in line with UL94 | V0 | 
| Insulation Materials | PA | 
| Insulation material group | I | 
| Requirements, voltage drop | Passed the test | 
| Voltage drop test results | Passed the test | 
| Temperature rise test results | Passed the test | 
| RoHS | No excessive harmful substances | 
| Connections are standard | IEC 60947-7-1 | 
| Standard test | IEC 60947-7-1 | 
| Pollution level | 3 | 
| Overvoltage class | III | 
| Rated voltage(III/3) | 690V | 
| Rated current(III/3) | 24A | 
| Rated surge voltage | 8kV |